商品详细WPI/微量注射注射器泵/SMARTouch控制器/normal/VAR-8091
WPI/微量注射注射器泵/SMARTouch控制器/normal/VAR-8091
WPI/微量注射注射器泵/SMARTouch控制器/normal/VAR-8091
商品编号: VAR-8091
品牌: wpiinc
市场价: ¥29440.00
美元价: 14720.00
产地: 美国(厂家直采)
公司:
产品分类: 显微镜
公司分类: Microscope
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Overview

Volume Discount

Delivering picoliter volumes precisely

  • Graphic display with SMARTouch™ touch screen controller for "intelligent", easy to use interface controlling up to four microlitersyringe pumps
  • Splash proof touch screen
  • User configurable mounting bar
  • Dual mode motor drive
  • Compatible with all UMP, UMP2 and UMP3 micro syringepumps
  • Optional foot switch available
  • 5 digit display

Details

Options

Order codeDescription
UMP3UltraMicroPump3 ONLY (without controller)
UMP3T-1UltraMicroPump3(one) and SMARTouch Controller
UMP3T-2UltraMicroPump3(two) and SMARTouch Controller
MICRO2TSMARTouch Controller ONLY, Two-Channel

Note on Accessory

*13142 is the foot pedal for use with the MICRO2T/MICRO4T ONLY. It is not compatible with the old MICRO4 controller, which uses the 15867 foot pedal. The two foot pedals are not cross-compatible.

Benefits

  • Accepts a wide range of microinjection syringes from 0.5 ul to 1000 ul.
  • Manual or automated injections
  • Quiet operation for electrophysiology recordings
  • Mounts directly on micromanipulator or stereotaxic frame
  • Nominal injections down to 1 nL
  • Rapid setup with intuitive touchscreen controller

Applications

  • Microinjection
  • Neuroscience
  • Microfluidics
  • Micro delivery of biochemical agents or dyes
  • Intravitreal Injection (with RPE-KIT)
  • Intraoccular Injection (with IO-KIT)

The UltraMicroPump3 (UMP3) is a versatile microinjection syringepump which uses micro syringes to deliver picoliter to milliliter volumes. The microinjection syringepump is optimum for applications that require injections of precise and small amounts of liquid. With its touchscreen controller, UMP3 microinjection syringe pumpcan displace as little as 0.53 µL/step (using 10 µL syringe with 60 mm scale length).

Patent Pending technology

The new SMARTouch™ controller for the UltraMicroPump3 features Patent Pending technology which includes:

  • Total system calibration – Calibrate the syringe and the controller together as a system. This feature eliminates the variability of the syringes and delivers the calibrated volume.
  • Smart smoothness – The controller can be set to automatically adjust microstepping according to the injection rate to deliver the smoothest flow.
  • User defined travel limits – Set the limits for a specific syringe in the software. This prevents the micro syringepump from over-driving the plunger into the syringe, potentially causing syringe breakage.

The MICRO2T SMARTouch™ controller is feature rich. All operations are controlled through interactive touch screen. It has a graphical indication of the flow and the volume remaining in the syringe. It offers end stop detection that is dependent on the syringe volume. You can control two pumps independently from one controller with its dual display. It also has automatic pump detection and a Pause/Resume feature that allows dosing during infusion/withdrawal. The volume accumulated is displayed on screen, as well as the percentage of volume left in the syringe. The SMARTouch™ controller is fully compatible with all earlier versions of the UltraMicroPump.

Low Fluid Dead Volume

Syringes may be filled externally and then inserted into the pump or filled while mounted in the micro syringepump. Fluids injected or withdrawn are held entirely within the micro syringe to maintain a low fluid dead volume.

Flexibility in Mounting

For positioning, the UMP3 microinjection syring pumpmay be attached to any of several WPI micropositioners such as the M3301 (manual), DC3001 (motorized) or any manual stereotaxic manipulator.

Rapid Setup with Intuitive Touchscreen Controller

An Integral component in the UMP3 system is the SMARTouch™ touchscreen controller, which provides an “intelligent” and easy-to-use interface up to two syringe pumps. Operating parameters are set with the touchscreen panel. An optional footswitch offers “hands free” start/stop operation.

Computer Control—A USB port on the rear of the controller can be used to connect it to a computer for scripted protocols.NOTE: UMP3 accepts glass syringes with barrel diameters from 5.5 to 9 mm.

Application Notes

The following images show various setups for microinjection. Keep in mind that parts are interchangeable.

UMP3T-2

UMP3T-2

The SMARTouch™ controller can control two UMP3 microliter syringe pumps or Nanoliter Injector pumps simultaneously, either grouped together or independently.

RPE Kit in a custom holder

RPE Kit in a custom holder

The RPE Kit is designed for retinal pigment epithelium injections in the eye, using a NanoFIl syringe mounted on the UMP3 microinjection pump. You get accurate, repeatable, oil free injections down to the submicroliter range.

UMP3 with MTM-3

UMP3 with MTM3

The UMP3 microinjection syringe pumpmay be mounted on any standard stereotaxic frame. Here the microinjection pump is mounted on our MTM-3 motorized stereotaxic frame.

Resources

UMP3 with MICRO2T Manual

Quick Start Guide for UMP3 with MICRO2T

Syringe Volume Calculation Spreadsheet - Use this .XLS spreadsheet to calculate the volume of your syringe when you are using an UMP3, DMP, MMP or PV820/PV830.

 

Specifications

Ultramicropump specifications

(based on 10 μL syringe)

Normal Mode
Travel62 mm
Minimum dispensing volume0.58 nL / step (10 µL syringe)
Linear motion per step3.175 µm/half step
Weight325 g (11.5 oz)
Mounting rod diameters7.9 mm (0.31 in.)
Mains power supply 90-264VAC @ 47-63Hz
Dimensions∅ 32 mm x 190 mm (∅ 1.3 in. x 7.5 in.)

 

Microstepping Mode
Precision is increased eight-fold.

 

References

Zhou, Z., Luther, N., Singh, R., Boockvar, J. A., Souweidane, M. M., & Greenfield, J. P. (2017). Glioblastoma spheroids produce infiltrative gliomas in the rat brainstem. Child’s Nervous System, 1–10. http://doi.org/10.1007/s00381-017-3344-y

Ye, H.-L., Li, D.-R., Yang, J.-S., Chen, D.-F., De Vos, S., Vuylsteke, M., … Yang, W.-J. (2017). Molecular characterization and functional analyses of a diapause hormone receptor-like gene in parthenogenetic Artemia. Peptides. http://doi.org/10.1016/j.peptides.2017.01.008

Wofford, K. L., Harris, J. P., Browne, K. D., Brown, D. P., Grovola, M. R., Mietus, C. J., … Cullen, D. K. (2017). Rapid neuroinflammatory response localized to injured neurons after diffuse traumatic brain injury in swine. Experimental Neurology, 290, 85–94. http://doi.org/10.1016/j.expneurol.2017.01.004

Qi, Y., Purtell, L., Fu, M., Zhang, L., Zolotukhin, S., Campbell, L., & Herzog, H. (2017). Hypothalamus specific re-introduction of Snord116 into otherwise Snord116 deficient mice increased energy expenditure. Journal of Neuroendocrinology. http://doi.org/10.1111/jne.12457

Mosberger, A. C., Miehlbradt, J. C., Bjelopoljak, N., Schneider, M. P., Wahl, A.-S., Ineichen, B. V., … Schwab, M. E. (2017). Axotomized Corticospinal Neurons Increase Supra-Lesional Innervation and Remain Crucial for Skilled Reaching after Bilateral Pyramidotomy. Cerebral Cortex, 137, 1716–1732. http://doi.org/10.1093/cercor/bhw405

Job, M. O., & Kuhar, M. J. (2017). CART peptide in the nucleus accumbens regulates psychostimulants: Correlations between psychostimulant and CART peptide effects. Neuroscience, 348, 135–142. http://doi.org/10.1016/j.neuroscience.2017.02.012

Eleftheriadou, I., Dieringer, M., Poh, X. Y., Sanchez-Garrido, J., Gao, Y., Sgourou, A., … Mazarakis, N. D. (2017). Selective transduction of astrocytic and neuronal CNS subpopulations by lentiviral vectors pseudotyped with Chikungunya virus envelope. Biomaterials, 123, 1–14. http://doi.org/10.1016/j.biomaterials.2017.01.023

Augestad, I. L., Nyman, A. K. G., Costa, A. I., Barnett, S. C., Sandvig, A., Håberg, A. K., & Sandvig, I. (2017). Effects of Neural Stem Cell and Olfactory Ensheathing Cell Co-transplants on Tissue Remodelling After Transient Focal Cerebral Ischemia in the Adult Rat. Neurochemical Research, 1–11. http://doi.org/10.1007/s11064-016-2098-3

Lin, P., Fang, Z., Liu, J., & Lee, J. H. (2016). Optogenetic Functional MRI. Journal of Visualized Experiments, (110), e53346–e53346. http://doi.org/10.3791/53346

Vacca, O., El Mathari, B., Darche, M., Sahel, J.-A., Rendon, A., & Dalkara, D. (2015). Using Adeno-associated Virus as a Tool to Study Retinal Barriers in Disease. Journal of Visualized Experiments, (98), e52451–e52451. http://doi.org/10.3791/52451

Lai, J., Legault, M.-A., Thomas, S., & Casanova, C. (2015). Simultaneous Electrophysiological Recording and Micro-injections of Inhibitory Agents in the Rodent Brain. Journal of Visualized Experiments, (101), e52271–e52271. http://doi.org/10.3791/52271

Robinson, S., & Adelman, J. S. (2015). A Method for Remotely Silencing Neural Activity in Rodents During Discrete Phases of Learning. Journal of Visualized Experiments, (100), e52859–e52859. http://doi.org/10.3791/52859

Platt, R. J., Chen, S., Zhou, Y., Yim, M. J., Swiech, L., Kempton, H. R., … Zhang, F. (2014). CRISPR-Cas9 Knockin Mice for Genome Editing and Cancer Modeling. Cell, 159(2), 440–55. http://doi.org/10.1016/j.cell.2014.09.014

Pierce, A. M., & Keating, A. K. (2014). Creating Anatomically Accurate and Reproducible Intracranial Xenografts of Human Brain Tumors. Journal of Visualized Experiments, (91), e52017–e52017. http://doi.org/10.3791/52017

Paveliev, M., Kislin, M., Molotkov, D., Yuryev, M., Rauvala, H., & Khiroug, L. (2014). Acute Brain Trauma in Mice Followed By Longitudinal Two-photon Imaging. Journal of Visualized Experiments : JoVE, (April), 1–8. http://doi.org/10.3791/51559

Nakamura, S., Baratta, M. V., & Cooper, D. C. (2013). A Method for High Fidelity Optogenetic Control of Individual Pyramidal Neurons <em>In vivo</em> Journal of Visualized Experiments, (79), e50291–e50291. http://doi.org/10.3791/50291

Inquimbert, P., Moll, M., Kohno, T., & Scholz, J. (2013). Stereotaxic Injection of a Viral Vector for Conditional Gene Manipulation in the Mouse Spinal Cord. Journal of Visualized Experiments, (73), e50313–e50313. http://doi.org/10.3791/50313

Hewing, N. J., Weskamp, G., Vermaat, J., Farage, E., Glomski, K., Swendeman, S., … Blobel, C. P. (2013). Intravitreal injection of TIMP3 or the EGFR inhibitor erlotinib offers protection from oxygen-induced retinopathy in mice. Investigative Ophthalmology & Visual Science, 54(1), 864–70. http://doi.org/10.1167/iovs.12-10954

Salt, A. N., Hartsock, J. J., Gill, R. M., Piu, F., & Plontke, S. K. (2012). Perilymph Pharmacokinetics of Markers and Dexamethasone Applied and Sampled at the Lateral Semi-Circular Canal. Journal of the Association for Research in Otolaryngology, 13(6), 771–783. http://doi.org/10.1007/s10162-012-0347-y

Nickerson, J. M., Goodman, P., Chrenek, M. A., Bernal, C. J., Berglin, L., Redmond, T. M., & Boatright, J. H. (2012). Subretinal delivery and electroporation in pigmented and nonpigmented adult mouse eyes. Methods in Molecular Biology (Clifton, N.J.), 884, 53–69. http://doi.org/10.1007/978-1-61779-848-1_4

Beier, K., & Cepko, C. (2012). Viral Tracing of Genetically Defined Neural Circuitry. Journal of Visualized Experiments, (68), e4253–e4253. http://doi.org/10.3791/4253

Goel, M., Sienkiewicz, A. E., Picciani, R., Wang, J., Lee, R. K., & Bhattacharya, S. K. (2012). Cochlin, intraocular pressure regulation and mechanosensing. PloS One, 7(4), e34309. http://doi.org/10.1371/journal.pone.0034309

Abdelwahab, M. G., Sankar, T., Preul, M. C., & Scheck, A. C. (2011). Intracranial Implantation with Subsequent 3D <em>In Vivo</em> Bioluminescent Imaging of Murine Gliomas. Journal of Visualized Experiments, (57), e3403–e3403. http://doi.org/10.3791/3403

Lowery, R. L., & Majewska, A. K. (2010). Intracranial Injection of Adeno-associated Viral Vectors. Journal of Visualized Experiments, (45), e2140–e2140. http://doi.org/10.3791/2140

Kinkel, M. D., Eames, S. C., Philipson, L. H., & Prince, V. E. (2010). Intraperitoneal injection into adult zebrafish. Journal of Visualized Experiments : JoVE, (42), e2126. http://doi.org/10.3791/2126

Molotkov, D. A., Yukin, A. Y., Afzalov, R. A., & Khiroug, L. S. (2010). Gene Delivery to Postnatal Rat Brain by Non-ventricular Plasmid Injection and Electroporation. Journal of Visualized Experiments, (43), e2244–e2244. http://doi.org/10.3791/2244

Marker, D. F., Tremblay, M.-E., Lu, S.-M., Majewska, A. K., & Gelbard, H. A. (2010). A Thin-skull Window Technique for Chronic Two-photon <em>In vivo</em> Imaging of Murine Microglia in Models of Neuroinflammation. Journal of Visualized Experiments, (43), e2059–e2059. http://doi.org/10.3791/2059

Eames, S. C., Philipson, L. H., Prince, V. E., & Kinkel, M. D. (2010). Blood sugar measurement in zebrafish reveals dynamics of glucose homeostasis. Zebrafish, 7(2), 205–13. http://doi.org/10.1089/zeb.2009.0640

Jasnow, A. M., Rainnie, D. G., Maguschak, K. A., Chhatwal, J. P., & Ressler, K. J. (2009). Construction of Cell-Type Specific Promoter Lentiviruses for Optically Guiding Electrophysiological Recordings and for Targeted Gene Delivery (pp. 199–213). http://doi.org/10.1007/978-1-59745-559-6_13

Christiana J. Johnson, Lennart Berglin, Micah A. Chrenek, T.M. Redmond, Jeffrey H. Boatright, J. M. N. (2008). Technical Brief: Subretinal injection and electroporation into adult mouse eyes. Molecular Vission, 14, 2211–2226. Retrieved from http://www.molvis.org/molvis/v14/a259/

Takayama, K., Torashima, T., Horiuchi, H., & Hirai, H. (2008). Purkinje-cell-preferential transduction by lentiviral vectors with the murine stem cell virus promoter. Neuroscience Letters (Vol. 443).

Torashima, T., Yamada, N., Itoh, M., Yamamoto, A., & Hirai, H. (2006). Exposure of lentiviral vectors to subneutral pH shifts the tropism from Purkinje cell to Bergmann glia. European Journal of Neuroscience, 24(2), 371–380. http://doi.org/10.1111/j.1460-9568.2006.04927.x

Torashima, T., Okoyama, S., Nishizaki, T., & Hirai, H. (2006). In vivo transduction of murine cerebellar Purkinje cells by HIV-derived lentiviral vectors. Brain Research, 1082(1), 11–22. http://doi.org/10.1016/j.brainres.2006.01.104

Dancause, N., Barbay, S., Frost, S. B., Plautz, E. J., Chen, D., Zoubina, E. V, … Nudo, R. J. (n.d.) (2005). Development/Plasticity/Repair Extensive Cortical Rewiring after Brain Injury. https://doi.org/10.1523/JNEUROSCI.3256-05.2005

Cherezov, V., Peddi, A., Muthusubramaniam, L., Zheng, Y. F., & Caffrey, M. (2004). A robotic system for crystallizing membrane and soluble proteins in lipidic mesophases. Acta Crystallographica Section D Biological Crystallography, 60(10), 1795–1807. http://doi.org/10.1107/S0907444904019109

Bernd, A. S., Aihara, M., Lindsey, J. D., & Weinreb, R. N. (2004). Influence of Molecular Weight on Intracameral Dextran Movement to the Posterior Segment of the Mouse Eye. Investigative Opthalmology & Visual Science, 45(2), 480. http://doi.org/10.1167/iovs.03-0462

Shawgo, R. S. (2004). In vivo activation and biocompatibility of a MEMS microreservoir drug delivery device. Retrieved November 16, 2016, from http://citeweb.info/20041104095

Nelson, B. P., Grimsrud, T. E., Liles, M. R., Goodman, R. M., & Corn, R. M. (n.d.) (2001). Surface Plasmon Resonance Imaging Measurements of DNA and RNA Hybridization Adsorption onto DNA Microarrays. https://doi.org/10.1021/ac0010431

Sturbaum, G. D., Reed, C., Hoover, P. J., Jost, B. H., Marshall, M. M., & Sterling, C. R. (2001). Species-Specific, Nested PCR-Restriction Fragment Length Polymorphism Detection of Single Cryptosporidium parvum Oocysts. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 67(6), 2665–2668.https://www.ncbi.nlm.nih.gov/pubmed/11375178

Accessories
More Choices:
  1. Sub-Microliter Injection System
    Sub-Microliter Injection System
    Multiple SKUs
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  2. NanoFil Needles
    NanoFil Needles
    Multiple SKUs
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  3. Optional Foot Switch for Micro2T, Micro-ePore™, DMF1000
    Optional Foot Switch for Micro2T, Micro-ePore™, DMF1000
    13142
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  4. V-clamp for UMP3
    V-clamp for UMP3
    502201
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  5. Nanofil Application Kits
    Nanofil Application Kits
    Multiple SKUs
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  6. FrameWorks V-Base Kit - Small
    FrameWorks V-Base Kit - Small
    503207
    For pricing, Customers outside of the US and Canada, please contact your distributor.
  7. Extension Cable for DLS100 and UMP3
    Extension Cable for DLS100 and UMP3
    503301
    For pricing, Customers outside of the US and Canada, please contact your distributor.
Video

UMP3 Pump now compatible with Hamilton Neuro Series7000 Syringe

Video demonstrating how to add NEW plunger button part number 65259 (Call for pricing)

Reviews
品牌介绍
WPI (World Precision Instruments Inc.,)是研发生命科学与医学科研仪器的领跑者,1967年在美国耶鲁大学(YaleUniversity)成立,总部位于美国佛罗里达州萨拉索塔市(Sarasota,Florida)。         WPI公司产品面广,产品线长,由60 年代初期的神经电生理产品,逐渐延伸到90 年代的生物感应器、光谱检测系列产品,到今天21 世纪再拓展到心血管生理、肌肉生理学和器官生理学等领域的产品,供应实验室产品种类超过5000种,是美国、英国、德国、加拿大、澳大利亚、新西兰、法国等欧美生命科学领域主流实验室仪器设备的重要供应商。近年来,WPI公司全新的肌肉生理学产品、全球*的单细胞肌肉张力测量系统、创新的生物荧光光谱测量系统等革新产品不断上市,满足了专家学者们更完善、更高效、更精确的研究需求。